How to Choose the Right Warehouse Workwear for Your Team
05/11/2026
Yash Agarwala
Associate Director – ACI Workwear
Yash Agarwala is a Associate Director at ACI Workwear, a company focused on manufacturing high-performance safety garments and industrial workwear. He is actively involved in scaling operations, improving manufacturing efficiency, and building global partnerships.
When shortlisting arc flash protective clothing manufacturers in India, start with a sample garment and the documents that support its label. Ask the supplier to identify the exact model, fabric or material system, test method and reported result. Then check that the sample and the proposed bulk order match the documented specification.
This guide covers the evidence to request, how to interpret an arc rating and what to verify before placing a bulk order.
Key Takeaway
- Start with the site’s task assessment and PPE requirements.
- Tie test evidence and labels to the exact garment or layered system.
- Check the scope of any licence or certification cited by the supplier.
- Approve a traceable sample before releasing the bulk order.
What Should You Verify Before Shortlisting a Manufacturer?
Look for traceability from the laboratory report to the garment you will issue. Ask for the report number, test standard and edition, tested specimen details, and a sample of the finished garment label. Check that the fabric, layer arrangement and garment model described in the supplier’s documents match the proposed order.
Under the ASTM route, ASTM F1959/F1959M determines the arc rating of clothing materials or material systems. Ask for that report and evidence that the finished garment meets ASTM F1506, which covers construction, performance and labelling as well as fabric requirements. Where design features need closer review, ASTM F2621/F2621M can show how the finished product responds to arc exposure at seams, closures, overlaps and trims. It does not assign an arc rating.
Under the IEC route, check the applicable test reports and evidence that the garment meets IEC 61482-2. Ask which material, garment or assembly the test report covers. The supplier evaluation checklist covers additional checks on sampling, production and batch records.
How Is Arc-Rated Clothing Different From FR Clothing?
Arc-rated clothing is flame resistant and has a measured arc rating. A flame-resistant (FR) label alone does not establish an arc rating. Some garments are made with inherently FR fibres and others use treated FR fabrics. Either type needs supporting test evidence for the arc performance claimed. ACI’s guide to inherent and treated FR fabrics explains how those fabrics differ in use and care.
Arc-rated clothing is designed to reduce thermal injury from an electric arc. Electrical shock and the pressure wave from an arc blast require separate controls and protection. Flash fire is a separate hazard, covered by standards such as NFPA 2112 for short-duration thermal exposure from fire. Where both hazards are present, buyers should request documentation for each.
If the label on your current coveralls is unclear, get in touch with ACI Workwear and share a photo of the label and the garment model. Our team can discuss which documents to request when comparing replacements.
Which Arc Flash Clothing Standards Should Indian Buyers Check?
The standards below cover different parts of the purchase, from workplace PPE selection to testing and garment requirements.
| Standard | What It Covers | What to Check |
| NFPA 70E | Electrical safe work practices and arc-flash PPE selection. | Your site’s risk assessment and the applicable PPE selection method. |
| ASTM F1959/F1959M | Open-arc test for clothing materials and material systems. | The report for the fabric or material system and its ATPV or EBT in cal/cm². |
| ASTM F1506 | Performance, construction and labelling requirements for protective clothing and its materials. | Garment conformity evidence and a label for the exact model. |
| IEC 61482-1-1 | Open-arc test for materials, garments or assemblies. | ELIM, ATPV and/or EBT, as reported, and the specimen tested. |
| IEC 61482-1-2 | Box test for materials and garments. | Arc protection class (APC 1 or 2). |
| IEC 61482-2 | Material and garment requirements for protection against the thermal hazards of an electric arc. | Model-specific conformity evidence and the applicable test reports. |
| IS 15742:2026 | Indian specification for clothing made of limited flame spread materials. | The licence scope where claimed. Obtain arc-test evidence separately. |
The IEC box test gives a protection class. Use an open-arc report when your purchasing specification calls for a value in cal/cm². APC 1 and APC 2 cannot be directly converted to a cal/cm² rating or an NFPA 70E PPE category. For arc- and flame-resistant rainwear purchased under the ASTM route, check ASTM F1891, which covers coated or laminated protective rainwear outside the scope of F1506.
IS 15405 (Part 1):2003 is the Indian adoption of the older IEC 61482-1:2002 test method. If it appears in a tender or report, verify the edition and confirm which method the specification calls for. In India, Regulation 21(2) of the Central Electricity Authority’s 2023 safety regulations addresses protective equipment for work on electric supply lines and apparatus. Check the requirements applicable to the site and use NFPA 70E as a PPE selection reference where adopted.
How Do You Match the Arc Rating to the Task?
Start with the task-specific electrical risk assessment. Establish an electrically safe work condition where required before work begins. Whether switching or testing calls for arc-rated PPE depends on the task, the equipment and its condition. Use the site’s assessment to specify the full PPE ensemble, including head, face, hand and hearing protection where required.
NFPA 70E provides two methods for selecting arc-flash PPE. Apply one method to the equipment.
- Incident-energy analysis. Where arc-rated clothing is required, select clothing or a tested system with a rating at least as high as the estimated incident energy at the working distance. Arc-flash studies commonly use IEEE 1584 for three-phase AC systems within its scope.
- PPE category method. Use the tables only when the equipment and task qualify and the limits for fault current, clearing time and working distance are met. Categories 1, 2, 3 and 4 specify minimum arc ratings of 4, 8, 25 and 40 cal/cm², respectively. Use an incident-energy analysis when the tables do not apply.
The 1.2 cal/cm² reference is used to define the arc-flash boundary. It does not establish the PPE category. If the purchase depends on a layered system, use the documented rating for the exact layers tested in that order. Adding the ratings printed on individual garment labels does not establish a system rating.
If your assessment specifies a rating or a layered system, use it to compare ACI Workwear’s FR and arc-resistant clothing range. Check the model, fabric or layer combination and ask for the matching documentation before approving a sample.
Where Do Indian Industries Use Arc-Rated Clothing?
Arc-rated clothing is relevant where the task assessment identifies an arc-flash exposure requiring that protection. Typical settings include electrical maintenance on motor control centres in manufacturing plants, work on switchgear in power stations and substations, and electrical tasks around large drives in steel plants. ACI’s electrical workwear overview shows examples of garment formats used in the sector.
Oil, gas and petrochemical facilities can have arc-flash and flash-fire exposures at the same site. Specify the protection for each job and area. For example, a refinery maintenance team may need a different garment specification for electrical work than for process-area duties.
What Should Buyers Check Before a Bulk Order?
A factory that makes its own fabric, a garment maker that sources tested fabric and an OEM can each supply traceable garments. Ask who manufactured the exact model and whose test report covers it. When buying through a distributor or under a private label, ask how the supplier links that model and label to the tested specification.
- Test evidence. Record the laboratory, report number, standard and edition, tested specimen and reported value or class.
- Material and construction. Verify the fabric code, fibre blend, weight, layer order, seams, sewing thread, closures and trims.
- Finished garment label. Check the model, claimed rating or class, applicable standard and care instructions.
- Layered systems. Request the report for the exact combination and order of layers being purchased.
- Batch traceability. Match the approved sample to production records, fabric lots and bulk-order labels.
- Certification scope. If the supplier cites a BIS licence or another certification, check which models or materials it covers.
Try on the pre-production sample before release. Check the fit over any required base layers, the overlap between garments and access to fasteners. ACI’s FR coverall guide covers fit and construction details to review at this stage.
How Should Arc-Rated Clothing Be Cared For?
Follow the garment’s care label and the manufacturer’s instructions for detergents, wash methods and drying. ASTM F1449 provides industrial laundering guidance for flame-resistant and arc-rated clothing. ASTM F2757 covers home laundering where the garment and employer’s programme permit it.
Inspect garments before use. Remove items with holes, burn damage, compromised seams or flammable contamination from service. Follow the manufacturer’s instructions for cleaning, repair and replacement. Return a contaminated garment to service only after effective cleaning and inspection. Issue dates and wash records support these decisions alongside the garment’s condition.
Why Consider ACI Workwear for Arc Flash Clothing?
ACI Workwear manufactures protective clothing at its facility in Unnao, Uttar Pradesh. Its range includes the Pro Light Coverall, 88/12 Pro Trouser and Ignite Blaze Suit. For a bulk order, specify the model, required standard, target rating or class and any custom branding or trim. Confirm that the quoted configuration is covered by the documentation submitted with the sample.
Conclusion
If you’re preparing a tender or replacing an existing issue, request a quote from ACI Workwear with your required standard, rating or class, garment type and quantities. That gives our team the details needed to discuss options and the documents to review before you place the order.
Frequently Asked Questions
1. Is Arc-Rated Clothing Fireproof?
Arc-rated clothing is designed to reduce thermal injury from an electric arc under defined conditions. Burns are still possible at the rated exposure, and protection varies with the actual exposure and clothing system.
2. Can Ordinary FR Coveralls Be Used for Arc Flash Work?
When the task requires arc-rated PPE, use coveralls or a tested clothing system with documented arc performance that meets the site’s selection criteria. An FR label alone is insufficient.
3. Does a BIS Mark Mean a Garment Is Arc Rated?
A BIS mark should be read against the specific licence and standard. IS 15742:2026 covers limited flame spread. Request the relevant arc-test report to verify arc performance.
4. What Is the Difference Between ATPV and EBT?
Arc thermal performance value (ATPV) is the incident energy associated with a 50% probability of reaching the predicted onset of a second-degree burn in the test. Breakopen threshold energy (EBT) is the incident energy associated with a 50% probability of material breakopen. Both are reported in cal/cm².
5. Which Arc Rating Is Needed for Electrical Panel Work?
Use the incident energy at the stated working distance or the applicable NFPA 70E PPE category when its table criteria are met. Equipment voltage alone cannot determine the rating.
6. How Long Does Arc-Rated Clothing Last?
Service life varies with use, laundering, contamination and garment condition. Follow the manufacturer’s instructions and the employer’s inspection and replacement criteria.
7. Can ACI Workwear Supply Custom-Branded Arc Flash Clothing?
ACI Workwear offers custom design and sampling. Confirm that the proposed logos, labels and trims are covered by the garment specification before approving the sample.